| Length: | 1715 mm |
|---|---|
| Width: | 670 mm |
| Height: | 1355 mm |
| Weight: | 105 kg |
| Actual Capacity: | 679 litres |
| Nominal Capacity: | 645 litres |
ERA Ratings
ERA is a new initiative that allows you to quickly and easily compare the relative risk of an environmental pollution incident originating from different types and different designs of fuel tanks and oil tanks. For more information, visit www.eraratings.org.uk.
This tank is rated as follows:
Product Summary
The world's most intelligent, high security bunded oil tank, manufactured from premium grade, medium density polyethylene. Bunded tanks consist of a 'tank within a tank' design and are the environmentally preferred option in heating oil tanks. iTank Pro tanks incorporate i-Track's accurate oil monitoring technology, enabling homeowners to track oil usage and spend per day/week/month/year as well as being informed on how many days until the tank runs dry. Finally, iTanks have a fuel alert system, which alerts the homeowner in the event of a sudden fuel loss or possible theft. This is enhanced by the iTank's 'This Tank is Alarmed!' sticker, supplied as standard. Spinsecure external tank lock and Harlequin Alarm Lock also suppled as standard.
The Harlequin Advance Bunded Oil Tank is supplied complete with:
- 2" Lockable Fill Point with Screw Cap
- 4” Lockable Inspection Aperture with Plastic Screw Cap
- 2” Vent
- Lockable Manhole Access
- Contents Dipstick
- i-Track IT9000 Intelligent Oil Monitoring System (calculates fuel levels and volumes several times per hour, displays litres remaining, tank contents as a percentage of overall capacity, number of days to empty, litres used per day/week/month/year, actual spend per day/week/month/year, CO2 emissions, date/time, internal temperature and oil storage temperature)
- LRC Failsafe Overfill Prevention Capability
- Lockable Manhole Access
- 1”BSP Bottom Outlet complete with Tank Fitting Kit - BND Bottom Outlet Bunded Oil Tank models only
- Atkinson 'Tank Top' Top Outlet System comprising Floating Suction Line; Non Return Valve; Fully Serviceable Filter; Anti-Siphon Valve; Self Prime Button; and choice of Compression or Push Fit Oil Line Connections – ITT Top Outlet Bunded Oil Tank models only
- Spinsecure External Tank Lock
- Harlequin 100db Alarm Lock
- Fuel Loss/Theft Alert System
- 'This Tank is Alarmed!' Sticker
This Bunded Oil Tank is suitable for the storage of heating oil at above ground storage installations at agricultural, commercial, domestic, industrial and institutional premises. It also satisfies or exceeds all applicable oil storage tank requirements detailed within:
- The Control of Pollution (Oil Storage) (England) Regulations 2001
- The Control of Pollution (Silage, Slurry and Agricultural Fuel Oil) Regulations 1991
- The Control of Pollution (Silage, Slurry and Agricultural Fuel Oil) Regulations (Northern Ireland) 2003
- The Water Environment (Oil Storage) (Scotland) Regulations 2006
- Environmental Alliance Pollution Prevention Guidelines PPG 2
- Oil storage tank installation requirements contained within Building Regulations throughout the UK and Republic of Ireland
Please note that this product is unsuitable for connection to a fuel delivery system incorporating a flexible hose and trigger nozzle. Please refer instead to Harlequin Bunded Fuel Point, Bunded Fuel Station or Bunded BioFuel Station ranges.
ITT Top Outlet Bunded Tanks
Top Outlet Bunded Oil Tanks are suitable only for connection to a fixed appliance incorporating a pressure jet burner with de-aerator, or dedicated oil lift equipment. If choosing a Top Outlet model, please contact the appliance manufacturer to confirm compatibility.
Installation Requirements
This product must be installed and maintained by an OFTEC Registered Technician or similarly competent person. (Instructions are supplied)
Clarehill Plastics Limited will not be responsible for oil tank installations which do not comply with the necessary requirements.
Tankmark is a nationwide network of independent storage tank technicians who can provide the complete tank installation and replacement service.
Click here to arrange a free no obligation, no hassle quotation for the supply and installation of your new Harlequin tank.
Where Can I Buy This Product?
Enter your details to find your local Harlequin reseller...
Important Information All Harlequin bunded oil tanks must be installed and maintained by a competent person, in accordance with manufacturer's instructions and prevailing statutory requirements. Clarehill Plastics Limited will not be responsible for installations that do not conform to these requirements. Please note that all images are supplied for reference purposes only. All dimensions and capacities stated are approximate and are understood to be correct at time of publication. However consistent our commitment to continual product improvement, the right is reserved to amend products without notice. Nominal capacities stated are equivalent to 95% of brimful volume.