Products – Bunded Fuel Points
2500SLFP Slimline Bunded Fuel Point
| Length: | 2550 mm |
|---|---|
| Width: | 1385 mm |
| Height: | 1985 mm |
| Weight: | 210 kg |
| Actual Capacity: | 2538 litres |
| Nominal Capacity: | 2411 litres |
At just 1385mm wide, the new 2500 litre Harlequin Slimline Fuel Point is ideal for smaller, commercial, industrial and agricultural storage installations where the added value technologies incorporated into the Fuel Station range, are not required.
Competitively priced, yet featuring the same high quality mouldings as the Fuel Station range, Harlequin Fuel Points offer a ‘no-nonsense’ specification. (Can also be used to store B7 Biodiesel).
Incorporating a door width of 750mm, the term ‘slimline’ applies only to the outer dimensions of the tank. In all other respects, customers can enjoy the same ease of access as with other, standard fuel point and fuel station models within the Harlequin range.
Product Overview:
- 4m Delivery Hose with automatic shut off nozzle
- 240V Ac Pump
- LRC Overfill Prevention Capability
- Lockable fill and inspection points
- Lockable equipment access
- Tank Vent
- Tank Contents Dipstick
Additional extra cost options:
- 10 micron particulate filter
- Mechanical flow metre
- Electronic contents gauge
- Cim-Tek Tank Dryer
- Harlequin Security Pack
ERA Ratings
ERA is a new initiative that allows you to quickly and easily compare the relative risk of an environmental pollution incident originating from different types and different designs of fuel tanks and oil tanks. For more information, visit www.eraratings.org.uk.
This tank is rated as follows:

Applications
Bunded Tank suitable for the storage and dispensing of Diesel and BioDiesel grades up to B5, produced in accordance with the requirements of BS/IS EN14214 at agricultural, commercial, industrial and institutional premises. Fully bunded, this tank satisfies or exceeds all applicable product requirements detailed within:
- The Control of Pollution (Oil Storage) (England) Regulations 2001
- The Control of Pollution (Silage, Slurry and Agricultural Fuel Oil) Regulations 1991
- The Control of Pollution (Silage, Slurry and Agricultural Fuel Oil) Regulations (Northern Ireland) 2003
- The Water Environment (Oil Storage) (Scotland) Regulations 2006
- Environmental Alliance Pollution Prevention Guidelines PPG 2
Installation Requirements
This Bunded Tank must be installed and maintained by a suitably competent person in accordance with supplied instructions and prevailing statutory requirements.
All mains electrical connections to this bunded tank, must be made only by an independently accredited electrician in accordance with prevailing electrical safety requirements and to an RCD protected power supply.
Tankmark is a nationwide network of independent storage tank technicians who can provide the complete tank installation and replacement service.
Click here to arrange a free no obligation, no hassle quotation for the supply and installation of your new Harlequin tank.
Where Can I Buy This Product?
Enter your details to find your local Harlequin reseller...
Important Information All Harlequin diesel storage tanks must be installed and maintained by a competent person, in accordance with manufacturer's instructions and prevailing statutory requirements. Clarehill Plastics Limited will not be responsible for installations that do not conform to these requirements. Please note that all images are supplied for reference purposes only. All dimensions and capacities stated are approximate and are understood to be correct at time of publication. However consistent with our commitment to continual product improvement, the right is reserved to amend products without notice. Nominal capacities stated are equivalent to 95% of brimful volume.